© 2007
Door & Access Systems
Publish Date: Summer 2007
Author: Joe Hetzel
Page 62
TECHNICAL TIPS
ASK JOE HETZEL
The Difference Between R-Value and U-Factor
Q: I’ve heard about a garage door’s U-factor.
What is that?
A: The U-factor is a measure of a door’s ability to
conduct or transmit the flow of heat from one side to the
other. This is different from R-value, which is related to
heat resistance.
When talking about a material, U-factor is the “inverse”
of R-value. This means that a U-factor of 0.10 is equivalent
to an R-value of 10.
Codes and standards show that door thermal performance is
based on the U-factor of entire door assemblies. Thus, door
section R-values do not indicate the complete door’s
thermal performance. You cannot simply take the inverse of
the section’s R-value to get U-factor for the entire
door.
Right now, an entire door assembly needs to be tested in
order to determine the U-factor. DASMA is working with others
to develop a reliable method of computer simulating that value.
|